Fire Resistance Classification |
EW 120 |
---|---|
Nominal thickness | 13mm |
Minimum production size | 200x200mm |
Max production size with nominal thickness | 2200x3000mm |
Max production size with nominal thickness | /bigger sizes upon request/ |
Maximum tested size | information on request |
Thickness tolerance | +2/-2 mm |
External thickness tolerance | +2/-2 mm |
Weight for minimum thickness | 29kg/m2 |
Temperature range | -10 / +45 C |
Light transmission | 87 % |
Sound reduction | Rw 38 dB |
U-value | UV 6,1 W/m2K |
UV stable | EN ISO 12543-3 Pt.6.5.2 |
G-value in % | 75 |
Shading coefficient SC | 0,86 |
Fire Resistance Classification |
El 30 |
El 60 |
El 90 |
---|---|---|---|
Nominal thickness | 16mm | 25mm | 39mm |
Thickness and external size tolerance | EN 12543 | EN 12543 | EN 12543 |
Weight for nominal thickness | 34kg/m2 | 53kg/m2 | 82kg/m2 |
Usage, storage & transportation temperature | -10 / +45 C | -10 / +45 C | -10 / +45 C |
Light transmission | 85% | 81% | 76% |
Sound reduction | Rw 38 dB | Rw 42 dB | Rw 45 dB |
G-value in % | 71 | 64 | 58 |
U-value | UV 5,7 W/m2K | UV 4,9 W/m2K | UV 4,2 W/m2K |
UV stable | EN ISO 12543-4 Pt.6 | EN ISO 12543-4 Pt.6 | EN ISO 12543-4 Pt.6 |
Impact resistance PN EN 12600 | 1 / B / 1 | 1 / B / 1 | 1 / B / 1 |
Fire rated panes are made of thermal tempered glass, this improves their damage resistance during transport, handling and installation.
It is not necessary to protect fire rated panes against UV rays by applying film or laminated glass.
Cross-sectional drawings are provided for reference only; designs may deviate from the presented ones.